Technical parameters

Covermaterial PTFE
Temperature range: -200... +260 °C
Surface pressure at 20 °C: min. 20 N/mm2, max. 500 N/mm2
Surface pressure at 300 °C1]: min. 30 N/mm2, max. 450 N/mm2

Covermaterial Graphit
Temperature range: -200... +500 °C
Surface pressure at 20 °C: min. 20 N/mm2, max. 500 N/mm2
Surface pressure at 300 °C1]: min. 30 N/mm2, max. 450 N/mm2

1] pay attention to the temperature limit of PTFE

Main application

  • For all flanges inside the main power flow
  • High level of temperature and pressure resistance

Suitable for

  • Power plants
  • Petrochemical plants
  • Chemical industry

Form of delivery

For Flanges according to DIN, PN 10-320 and DIN 2697:

  • ANSI flanges B 16.5 and MS-SP 44
  • Tongue/groove flanges according to DIN 2691 or ANSI B 16.21
  • Male/female flanges according to DIN 2692
  • Flanges following API Std. 605. Dimensions according to ANSI B 16.21

D 7 ProCor
D 7 ProCor Camprofile Gasket, profiled metal base covered with graphite or PTFE layer, optional with or without center ring(s).

Characteristics

  • For flange connections in high pressure piping and in fittings
  • Extremely low leakage values with PTFE inlay. Helium leakproof 10 - 8 mbar l/(ms)
  • High temperature resistance up to 550 °C with graphite inlay
Back