Operating range

Pressure [pmax]: Vacuum … 55 bar
pH: 0 - 14

Temperature: t = -240… +270 °C

Pressure: Vacuum up to 55 bar (according to the operational and/or assembly conditions)

Temperature: Resistance of the ePTFE sealing material short term +310 °C. After first temperature exertion the bolts should be Re-tightened.

Resistant

  • All media pH 0-14, e.g:
    acids, alkaline, solvents, paint, oil, grease, steam
  • Excluded:
    molten and/or solved alkaline metals and elementary or gaseous fluoride at high temperature or under high pressure
  • Ageing resistant

Material

100 % pure ePTFE in a stretched filament knotted fibre structure. This ensures that there is a high pressure resistance (restricted cold flow) and a good adaptation to the flange surface.

Main application

  • Pipe Columns
  • Separation joints
  • Mixer
  • Pump Housing
  • Machine Housing
  • Glass- and Graphite-Devices
  • Lined vessels
  • Sight glasses
  • Hand- and Manhole covers (Not TRD401)
  • Ventilation and Air Condition Channels
  • Steel and Plastic flanges
  • Pipes and devices with highly aggressive chemicals
  • Gearboxes

Suitable for

  • Chemical industry
  • Pharmaceutical industry
  • Food industry
  • General service

Approvals

  • TÜV Prüfung acc. MUC-KSP-A066
  • BAM for oxygen 60 °C / 40 bar
  • DVGW Reg.-Nr.: DG-5127CL0032
  • TA-Luft: AMTEC 1.7 · 10-7 mbar · l/(s·m) @ 250 °C test pressure

Food:

  • FDA21 CFR 177.1550 (PTFE)
  • FDA21 CFR 170.105 (adhesive)
  • EG 1935:2004 EU 10/2011
Registered users can view stock information

D 1 Protex
ePTFE Gasket

Characteristics

  • Simple to install
  • No ageing of the ePTFE Joint Sealant
  • Excellent adaption, ideal to compensate uneven gland surfaces
  • Physiologically safe in temperatures up to +260 °C
  • Selection criteria: unevenness of gland should not be bigger than 1/3 of seal thickness

Dimensions

Order Code Width/Height (mm) Standard Roll Length (mtr) Recommended for flange width Surface pressure/result. thickness (mm)
        10/mm2 20/mm2 30/mm2
D 1/1 1 x 1/td> 25   0.15 0.10 0.08

D 1/3

3 x 1,5

25

< NW 100

0.40

0.35

0.30

D 1/5

5 x 2

25

< NW 300

0.80

0.60

0.50

D 1/7

7 x 2,5

25

< NW 800

1.00

0.80

0.70

D 1/10

10 x 3

25

< NW 1,500

1.20

0.90

0.80

D 1/12

12 x 4

10

< NW 1,500

1.45

1.15

0.95

D 1/14

14 x 5

10

> NW 1,500

1.60

1.20

1.00

D 1/17

17 x 6

10

         

In case of
bigger unevenness
use next bigger
thickness or apply
a double layer
oder unterfüttern

2.10

1.50

1.40

D 1/20

20 x 7

10

2.40

1.80

1.40

D 1/25

25 x 5

5

1.60

1.20

1.00

D 1/25DD

25 x 8

5

2.74

2.06

1.60

D 1/28

28 x 5

5

1.60

1.20

1.00

D 1/40

40 x 5

5

1.60

1.20

1.00

            

Reference Values: Depending on flange surface condition. Gas Tight above 20 N/mm2 during operation conditions.

            