Operating range

Pressure [pmax]: Vacuum … 200 bar
pH: 0 - 14
Density 0.65 g/cm³

Temperature: t = -200… +280 °C

After first temperature exposure the bolts should be Re-tightened.

pH-Value chem. Resistance: Except molten or dissolved alkaline metals, elementary or dissolved fluorine under high pressure.

Main application

  • Larger flanges and vessels
  • Glaslined flanges
  • Agitators
  • Heat exchangers

Form of delivery

  • 10 mtr / roll
  • Other length and dimension on request

Suitable for

  • Chemical industry
  • Pharmaceutical industry
  • Food industry
  • General service

Approvals

  • FDA21 CFR 177.1550 (PTFE), FDA21 CFR 170.105 (adhesive) EG 1935:2004 EU 10/2011
  • TA Luft VDI 2440

Installation Instructions

  • Connect the ends with an angle cut
  • Maximum uneveness of flange: 1/3 of seal tape’s thickness
Registered users can view stock information

D 11 Probitex
Compression Proof and Form Stable Biaxial expanded gasket tape with adhesive backing

Characteristics

  • No change in width at compression
  • Excellent on slim or restricted flange area
  • No ageing
  • Excellent adaption to flange uneveness
  • Physiologically safe in temperatures up to +260 °C
  • Practical waste-free application

Available Dimensions D11: (other dimensions on request)

width thickness in
(mm) 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm 10 mm
10 x x x x x x x x x
15 x x x x x x x x x
20 x x x x x x x x x
25 x x x x x x x x x
30 x x x x x x x x x
35 x x x x x x x x x
40 x x x x x x x x x
45 x x x x x x x x x
50   x   x x x x x x
55   x     x x x x x
60   x     x x x x x

Compression Values

thickness
(mm)
Recommended for Steel Flanges 
width according EN1514-1 (NW)
Surface pressure/ resulting thickness in 
10 N/mm2 20 N/mm2 30 N/mm2 40 N/mm2
2 ≤ 300 0.94 0.76 0.70 0.66
3 ≤ 800 1.57 1.14 1.05 0.99
4 ≤ 800 1.88 1.52 1.40 1.32
5 ≤ 800 2.35 1.90 1.75 1.65
6 ≤ 1500 2.82 2.28 2.10 1.98
7 ≤ 1500 3.29 2.66 2.45 2.31
8 ≤ 1500 3.76 3.04 2.80 2.64
9 ≤ 1500 4.23 3.42 3.15 2.97
10 > 1500 4.70 3.80 3.50 3.30
Back