Operating range
Velocity [vmax]: | 12 m/s |
pH: | 2 - 12 |
Density | 1.10 g/cm³ |
Temperature: t = -40… +315 °C
Pressure Capability is dependent on design of endrings.
Suitable for
- Higher Temperature applications
Main application
- Equipment which is badly accessible
- Worn shaft sleeves
- Non centric running shafts
Functional Description
Due to the special fibre compound and the proprietary lubricant mix, the Sealing Compound System DVS is suited to seal stuffing boxes with low pressure. The loose compound will be hold in place by a top and bottom ring, typically made of hydrolysed polyurethane HPU with a special developed geometry. Therefore extrusion of the Sealing compound is prevented and can not cause a premature failure of the DVS Sealing Compound System. Contrary to braided packing the DVS needs little maintenance only. Due to its loose and pliable structure it is absolutely gentle to the shaft or shaft sleeve surface. Preferrably used on worn shafts and in offset or concentric shaft orientations.
Accessories
Top and bottom HPU Endrings:
· Material HPU machined according to customer measurement
· Note: HPU is of allround use, please check if other compound is needed due to chemical or temperature in the application.
DVS-Injection Press:
· DVS TP 8200 Spindle Injection Press
· DVS TP 9001 Hydraulic press
DVS top and bottom Endring / DVS HPU STANDARD made of HPU, split or unsplit
DVS top and bottom Endring / DVS HPU UNIVERSAL - unsplit made of HPU and PTFE / Graphite compound. Can run on non centric running shafts.
DVS top and bottom Endring / DVS HPU UNIVERSAL - radially split made of HPU and PTFE / Graphite compound. Can run on non centric running shafts.
2 Component System
Component H:
Is used for the basic manual fill of the stuffing box.
Component P:
Is used for Injection with press DVS TP 9001.
Form of delivery
Unit for H- and P-Type:
Cans 1 kg,
Hobbock of 20 kg
DVS-SP30
2 Component Fiber Sealing System impregnated with Graphite and MoS2 lubricant
Characteristics
- Simple installation
- Use without barrier fluid
- Maintenance free
- Shaft protecting
- No adjusting of gland
- Re-pressurize in operation