Operating range

Kreiselpumpe Pressure [pmax]: 10 bar
Velocity [vmax]: 10 m/s
Plunger Pressure [pmax]: 50 bar
Velocity [vmax]: 1 m/s
Armatur Pressure [pmax]: 50 bar
pH: 5 - 9
Density 1.45 g/cm³

Temperature: t = -20… +100 °C

Main application

  • Centrifugal pumps
  • Mixer

Suitable for

  • Universal use in lower temperature range
  • Pulp and paper industry
  • General plant maintenance
  • Sewage plants

Form of delivery

Registered users can view stock information

This packing can be manufactured from 6 to 30 mm square as well as in intermediate, inch sizes and special measurements.

06 - 09 mm on 1 kg spool
10 - 15 mm on 2,5 kg spool
16 - 25 mm on 5 kg spool

Special length on request.

1 kg of packing of the following cross-sections corresponds to displayed meter lengths:

Size mm["]Meter
619.2
6.35 [1/4"]17.1
714.1
8 [5/16"]10.8
9.5 [3/8"]7.6
106.9
11 [7/16"]5.7
Size mm["]Meter
124.8
12.7 [1/2"]4.3
14 [9/16"]3.5
153.1
16 [5/8"]2.7
182.1
19 [3/4"]1.9
201.7
22 [7/8"]1.4
25 [1"]1.1

P 83
Cotton with tallow/grease and Run-In Lubricant

Characteristics

  • Universal packing for the lower temperature range
  • Excellent cost-value relation
  • Recommended shaft surface hardness: HRC 45
  • For products containing solids
  • Highly pliable packing
Back