Operating range

Kreiselpumpe Pressure [pmax]: 25 bar
Velocity [vmax]: 15 m/s
Plunger Pressure [pmax]: 1,500 bar
Velocity [vmax]: 2 m/s
Armatur Pressure [pmax]: 500 bar
pH: 2 - 12
Density 1.35 g/cm³

Temperature: t = -100… +280 °C

Practical useful application data:

max. temperature: +200 °C

Main application

  • Plunger pumps

Suitable for

  • High pressure plunger pumps and similar applications
  • Bull rings

Form of delivery

Registered users can view stock information

This packing can be manufactured from 6 to 40 mm square as well as in intermediate, inch sizes and special measurements.

06 - 09 mm on 1 kg spool
10 - 15 mm on 2,5 kg spool
16 - 25 mm on 5 kg spool

Special length, pre-cut or die formed rings on request.

1 kg of packing of the following cross-sections corresponds to displayed meter lengths:

Size mm["]Meter
620.6
6.35 [1/4"]18.4
715.1
8 [5/16"]11.6
9.5 [3/8"]8.2
107.4
11 [7/16"]6.1
Size mm["]Meter
125.1
12.7 [1/2"]4.6
14 [9/16"]3.8
153.3
16 [5/8"]2.9
182.3
19 [3/4"]2.1
201.9
22 [7/8"]1.5
25 [1"]1.2

S 43 K Hochdruck Extra
ePTFE-Graphite Fiber with special Para-Aramid corners and Paraffin Run-In Lubricant

Characteristics

  • Form stable, wear resistant, heat conductive packing, can be used as bullring
  • Highest pressure resistance, practically no gap extrusion
  • For high pressure plunger pumps up to 1,500 bar as die formed rings
  • Highest pressure resistance
  • Safe and universal packing for abrasive media
  • Precompressed rings are recommended for applications in plunger pumps

Variant

S12 K for lower pressure ranges

Back